Reference ranges of electrolyte and anion gap on the Beckman E4A, Beckman Synchron CX5, Nova CRT, and Nova Stat Profile Ultra
PH Lolekha, S Vanavanan, N Teerakarnjana… - Clinica chimica acta, 2001 - Elsevier
… higher than the values obtained from the Beckman analyzers. For the anion gap, the reference
ranges in this … However, our reference ranges were lower than the previous reference …
ranges in this … However, our reference ranges were lower than the previous reference …
[HTML][HTML] Data on the clinical, analytical, and laboratory factors associated with negative anion gaps at an academic medical center
JM Laakman, ZJ Fleishhacker, MD Krasowski - Data in Brief, 2022 - Elsevier
… anion gap reference ranges in children [7]. We did not find any publications on reference
range or distribution of anion gap … Although many anion gap equations of various complexities …
range or distribution of anion gap … Although many anion gap equations of various complexities …
Ion-selective electrode and anion gap range: What should the anion gap be?
SA Sadjadi, R Manalo, N Jaipaul… - International Journal of …, 2013 - Taylor & Francis
… in the 1970s, the normal value of anion gap (AG) was determined … (ISE), the anion gap
value has fallen to lower levels. … (Beckman Coulter) was 107 meq/L, while the reference serum …
value has fallen to lower levels. … (Beckman Coulter) was 107 meq/L, while the reference serum …
Comparability of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods
Z Flegar-Meštrić, S Perkov - Clinical Chemistry and Laboratory …, 2006 - degruyter.com
… of electrolytes and substrates in whole blood using a Stat Profile Critical Care Xpress (Nova
Biomedical, … The Stat Profile Critical Care Xpress analyzer was used to obtain whole-blood …
Biomedical, … The Stat Profile Critical Care Xpress analyzer was used to obtain whole-blood …
Correction of the anion gap for albumin in order to detect occult tissue anions in shock
M Hatherill, Z Waggie, L Purves, L Reynolds… - Archives of disease in …, 2002 - adc.bmj.com
… Serum electrolytes were measured by a Beckman Syncron … were measured by a Beckman
Syncron CX5 analyser, using … Therefore, since the reference range for serum chloride has …
Syncron CX5 analyser, using … Therefore, since the reference range for serum chloride has …
Comparative study of values of calculated bicarbonate and measured total carbon dioxide content
PH Lolekha, W Boonlert, GJ Kost, S Vanavanan… - Point of …, 2003 - journals.lww.com
… obtained from the Nova Stat Profile Ultra C (SP… value, such as the anion gap and base
excess. Previous studies used measured TCO 2 to establish the reference interval of the anion gap…
excess. Previous studies used measured TCO 2 to establish the reference interval of the anion gap…
Use of the ΔAG/ΔHCO3− Ratio in the diagnosis of mixed acid-base Disorders
A Rastegar - Journal of the American Society of Nephrology, 2007 - journals.lww.com
… quantitative relationship between excess anion gap (ΔAG) … normal range for the AG varies
from 3 to 11 to 8 to 16 mEq/L, depending on the instrument used to measure serum electrolytes…
from 3 to 11 to 8 to 16 mEq/L, depending on the instrument used to measure serum electrolytes…
Diagnostic threshold and performance of anion gap in screening for high anion gap metabolic acidosis
CY Chionh, CSY Tien, W Yeon - Singapore Medical Journal, 2024 - journals.lww.com
… Anion gap reference intervals show instrument dependence and weak correlation with
albumin levels. … Serum anion gap revisited: A verified reference interval for contemporary use. …
albumin levels. … Serum anion gap revisited: A verified reference interval for contemporary use. …
Severe acidosis caused by starvation and stress
HL Toth, LA Greenbaum - American Journal of Kidney Diseases, 2003 - Elsevier
… anion gap of 8 to16 mEq/L was once thought to be normal, 3 to 11 mEq/L is a more accurate
normal range … .3, 27, 28 Thus, our patient had an increased anion gap. The increase in the …
normal range … .3, 27, 28 Thus, our patient had an increased anion gap. The increase in the …
Calculation of the total plasma concentration of nonvolatile weak acids and the effective dissociation constant of nonvolatile buffers in plasma for use in the strong ion …
SM McCullough, PD Constable - American journal of veterinary …, 2003 - Am Vet Med Assoc
… Reference ranges of electrolyte and anion gap on the Beckman E4A, Beckman Synchron
CX5, Nova CRT, and Nova Stat Profile Ultra. Clin Chim Acta 2001;307:87–93. …
CX5, Nova CRT, and Nova Stat Profile Ultra. Clin Chim Acta 2001;307:87–93. …